On 3/21/2017 11:12 PM, Mike Horvath wrote:
> The CMFs I am currently using are in 5nm steps from 360nm to 830nm,
> which is 95 steps total.
>
> Are there more detailed samples? Are there more detailed samples for D65
> illumination too? The CMFs and illuminations should have the same number
> of steps in the same range, since my script is set up to iterate through
> both sets of samples at the same time. Not sure what to do if the sample
> tables aren't the same sizes.
>
> Thanks.
>
>
> Mike
Wikipedia says you can just interpolate between the 5nm points to
generate narrower ones. Lightsys uses a spline apparently.
Mike